The C 6000 global standards oxygen bomb calorimeter combines modern technology, variability and automation (adiabatic, isoperibol; dynamic modes) in one instrument. It operates according to all bomb calorimeter standards, such as e.g. the DIN, ISO, ASTM, GOST and GB. The operator can choose between three different starting temperatures (22 ºC, 25 ºC, 30 ºC) in each measuring mode: adiabatic, isoperibol or dynamic. Due to the spherically shaped decomposition vessel head, the wall thickness was able to be reduced, allowing for faster heat transfer which results in a shorter time measurement. Due to the variety of different interfaces (PC, Ethernet, SD-card, balance, printer) this unit is easily adaptable depending on the customer’s specific application needs. Further adaption to data management and LIMS is possible with our calorimeter software C 6040 Calwin (Accessory).
- Automatic ignition
- Automatic water filling and draining
- Automatic oxygen filling, venting and flushing
- RFID technology for automatic decomposition vessel identification
- New design of the decomposition vessel allows for easier and faster sample preparation
- Can be operated with a chiller (e.g. KV 600)
- Easy and convenient touch screen operation
- Control chart view and correction calculation of globally used standards
- Ethernet interface for data management via FTP server or connection of a network printer
- Removable SD-card allows for easier data measurement management, in addition to software updates
The C 6000 global standards Package 2/10 consists of:
- C 6000 global standards (0003780000)
- C 6010 Decomposition vessel, standard (0003770000)
Voltage: |
220 - 240V |
Width: |
500mm |
Working temperature max. : |
0°C |
Temperature measurement resolution : |
0.0001K |
Oxygen operating pressure max. : |
40bar |
Cooling medium temperature min.: |
12°C |
Frequency: |
50/60Hz |
Permissible relative humidity: |
80% |
Measurements/h isoperibol: |
4 |
Measurements/h dynamic: |
6 |
Measuring mode adiabatic 22°C: |
yes |
Measuring mode adiabatic 25°C: |
yes |
Measurements/h adiabatic: |
5 |
Measuring mode adiabatic 30°C: |
Yes |
Permissible ambient temperature max.: |
30°C |
Measuring range max.: |
40000J |
Cooling medium temperature max.: |
27°C |
Working temperature min. : |
22°C |
Rec. flow rate at 18°C: |
60l/h |
Height: |
425mm |
Power input: |
1700W |
Weight: |
29kg |
Reproducibility dynamic (1g benzoic acid NBS39i): |
0.15%RSD |
Reproducibility adiabatic (1g benzoic acid NBS39i): |
0.05%RSD |
Cooling medium permissible operating pressure: |
1.5bar |
Reproducibility isoperibol (1g benzoic acid NBS39i): |
0.05%RSD |
Flow rate min. : |
60l/h |
Flow rate max.: |
70l/h |
Permissible ambient temperature min.: |
20°C |
Depth: |
450mm |
Chiller: |
RC 2 basic |
Decomposition vessel C 6010: |
yes |
Interface printer: |
USB |
Interface scale: |
RS232 |
Interface PC: |
RS232 |
Interface test rack: |
yes |
Oxygen filling: |
yes |
Interface ext. keyboard: |
yes |
Cooling medium: |
tap water |
Measuring mode isoperibol 30°C: |
yes |
USB interface: |
yes |
RS 232 interface: |
yes |
Type of cooling: |
Flow |
Measuring mode isoperibol 22°C: |
yes |
Measuring mode dynamic 30°C: |
yes |
Measuring mode dynamic 25°C: |
yes |
Degasification: |
Yes |
Decomposition detection: |
yes |
Analysis according to DIN EN ISO 1716: |
yes |
Analysis according to GB T213: |
yes |
Analysis according to DIN EN 15170: |
Yes |
Analysis according to DIN CEN TS 14918: |
yes |
Touchscreen: |
yes |
Analysis according to DIN EN ISO 9831: |
yes |
Measuring mode dynamic 22°C: |
yes |
Measuring mode isoperibol 25°C: |
Yes |
Analysis according to ASTM D240: |
yes |
Analysis according to DIN 51900: |
yes |
Analysis according to ASTM D4809: |
Yes |
Analysis according to ASTM D5865: |
yes |
Analysis according to ISO 1928: |
yes |
Analysis according to ASTM E711: |
yes |
Protection class according to DIN EN 60529: |
IP 20 |